PROTECH ENGINEERING
| Products : |
Engineering Goods And Equipment Trading House |
Address : |
E 12 NANDJYOT IND ESTATE ANDHERI KURLA ROAD SAFED POOL SAKINAKA ANDHERI(E) |
Telephone : |
85133282084562 |
Fax : |
8560589/2065651 |
Send : |
On-Line Trade Inquiry |
|
Products |
3 IMPULSE RELAY - USES DIGITAL ICS TO GIVE COMPACT ADJUSTABLE CYCLIC AND STAR DELTA TIMERS CHOICE OF DUAL POWER SUPPLY 230 V AC/24 V D C IN GT2 SERIES 3 IMPULSE RELAY FREE FROM EFFECTS OF SURGES WORKS WITH SAME ACCURACY EVEN WITH VARIATION OF + 30% IN POWER SUPPLY. READY STOCK FOR 12V D.C & 24 D.C. MODELS.
|
AUTOMATIC BATTERY CHARGER - PRESENTED BY PROTECH ENGINEERING THE AUTOMATIC BATTERY CHARGER IS AN INNOVATIVE VENTURE.. MODEL PE/ABC/D-897 IS AN AUTOMATIC BATTERY CHARGER. ITS TECHNICAL SPECIFICATIONS ARE AS FOLLOWS INPUT - 1 PHASE, 230 V ±10%, 50 HZ, AC SUPPLY OUTPUT - 12 V, 24 V (OR AS PER THE NEEDT), 10 A, 15 A; FLOAT/BOOST CHANGEOVER - AUTOMATIC BY PROLOGIC ON PRIMARY SIDE OF TRANSFORMER; TYPE OF RECTIFIER - FULL WAVE BRIDGE (SILICON); TYPE OF TRANSFORMER - DOUBLE WOUND TYPE; PROTECTIONS - BY FUSES AGAINST SHORT CIRCUIT, REVERSE POLARITY; INDICATIONS - VOLTAGE, CURRENT ON METERS, MAINS ON, CHARGING ON, REVERSE POLARITY; FLOAT/BOOST MODE - ON PROLOGIC; AUTO/MANUAL MODE; DIMENSIONS - 275 MM (W) X 325 (H) X 320 (D) MM; AND WEIGHT - 18 KG MAXIMUM.
|
BATTERY CHARGER PE/BC8 - PROTECH ENGINEERING MAKES A RANGE OF BATTERY CHARGERS FOR DG SETS AND SIMILAR APPLICATIONS. MODEL PE/BC-897 BATTERY CHARGER HAS THE FOLLOWING TECHNICAL SPECIFICATIONS: INPUT - 1 PHASE, 230 V ±10%, 50 HZ, AC SUPPLY; OUTPUT - 12 V, 24 V (OR AS PER THE NEED ), 10 A, 15 A; FLOAT/BOOST CHANGEOVER - MANUAL BY ROTARY SWITCH; TYPE OF RECTIFIER - FULL WAVE BRIDGE (SILICON); TYPE OF TRANSFORMER - DOUBLE WOUND TYPE; PROTECTIONS - BY FUSES AGAINST - SHORT CIRCUIT - REVERSE POLARITY; INDICATIONS - VOLTAGE, CURRENT ON METERS, MAINS ON, CHARGING ON AND REVERSE POLARITY; DIMENSIONS - 275 MM (W) X 325 (H) X 320 (D) MM; AND WEIGHT - 18 KG MAXIMUM.
|
START-ON DELAY TIMERS - PROTECH ENGINEERING & CONTROLS PVT LTD OFFERS STAR-ON DELAY TIMERS (TYPE G22-SOD) ESPECIALLY DESIGNED FOR TIME DELAY IN A VARIETY OF APPLICATIONS, WHERE TIMERS REMAIN IN THE CIRCUIT FOR START DELAY TIME ONLY. THESE DELAY TIMERS HAVE TWO CONTACTS, ONE USED FOR LATCHING THE TIMER SUPPLY (INSTANTANEOUS), AND THE OTHER CONTACT WILL BE ON FOR 100 MSECS. TO START THE CONTACTORS THEY HOLD THROUGH THE CONTACTORS THEY HOLD THROUGH THE CONTACTORS CONTACT ITSELF. BOTH THE CONTACTS BECOME OFF THUS THE TIMER COIL IS ALSO OUT OF THE CIRCUIT, INCREASING THE VIRTUAL LIFE OF TIMERS. THESE TIMERS ARE PERFECTLY APT FOR TIME DELAY IN STARTER AND CAPACITOR SWITCHING APPLICATIONS.
|
REVERSE/FORWARD TIMERS - REVERSE/FORWARD TIMERS MANUFACTURED BY PROTECH ENGINEERING ARE USED FOR INDUSTRIAL APPLICATIONS. ITS AVAILATIES HAVE ONLY REVERSE/FORWARD TIMER WITH SCREW LESS VIBRATION PROOF TERMINALS; ADJUSTABLE AND FIX TYPE FORWARD/REVERES TIME AND PAUSE TIME; TAILOR-MADE SOLUTION FOR USES LIKE LAUNDRY WASHING MACHINES AND OTHER CHEMICAL PUMPS; USES DIGITAL ICS TO GIVE ACCURATE REPEAT CYCLES; WIRELESS INTERIORS MAKES IT MORE RUGGES AND ERROR PROOF; SMART MACHANICAL DESIGN TO FIT ON ANY STANDARD MOUNTING CHANNEL; AND PROFESSIONALLY DESIGNED TO USE FLUSH AS WELL AS PANEL MOUNTING TECHNICALLY ITS OUTPUT CONTACT-ONE CHANGE OVER CONTACT FOR FORWARD AND ONE CHANGE OVER CONTACT FOR REVERSE; SWITCHING DUTY-6A RESISTIVE AT 240V AC OR 24V DC; ELECTRICAL LIFE- 10 OPERATIONS AT MENTIONED DUTY CYCLE; OPERATING VOLTAGE-415/380/220/110V AC;PERMISSIBLE VOLTAGE VARIATION -25%; POWER CONSUMPTION -15VA (MAX); RESET TIME-100 M SEC, MAX;REPEAT ACCURACY -0.5% FS; SETTING ACCURACY -5% OF FULL SCALE, ETC.
|
THREE IMPULSE RELAY - IT IS SPECIALLY DEVELOPED FOR ENGINE STARTING APPLICATIONS LIKE DG SET AND FIRE FIGHTING PUMPS,ETC. FEATURES ARE IT IS FREE FROM EFFECTS OF SURGES; WORKS WITH SAME ACCURACY EVEM WITH VARIATION OF 30% IN POWER SUPPLY; RELAY ON/OFF INDICATIONS ON FRONT FOR ASSISTING TIME SETTINGS; AND READY STOCK FOR 12/24 V DC MODELS. TECHNICAL INFORMANTION OUTPUT CONTECT- A)1 CHANGE OVER (RL1) ON/OFF ADJUSTABLE CONTACT, B)1 CHANGE OVER (RL2) FOR ALARM OR INDICATION AFTER IMPULSES COMPLETES; SWICHING DUTY-6A RESISTIVE AT 240 V AC OR 24 V DC; ELECTRICAL LIFE-10 OPERATIONS AT RATED SWITCHIN DUTY; OPERATING VOLTAGE-12V DC/24V DC (CAN BE MADE FOR OTHER VOLTAGE); PERMISSIBLE VOLTAGE-25%; POWER CONSUMPTION-10 VA (MAX); RESET TIME-100 MSEC MEX; REPEAT ACCURACY-0.5% FS; SETTING ACCURACY-5% OF FS; LED INDICATIONS-POWER ON, RL1 ON, RL1 OFF, AND RL2 ON; MOUNTING-70 (W) X 110 (H) X 100 (D)MM.
|
|
|